ADS Environmental Services Profile Software 950015B6 User Manual
Page 73

Profile Main Screen
2-33
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 - 2012 ADS LLC. All Rights Reserved.
Edit data delivery setup
• Mode Select the destination to which you want the monitor
to deliver the data. This list includes an IntelliServe database
or an existing FTP site. To deliver data to an IntelliServe
database, you must enter the IP address for the IntelliServe
system in the IP Address field of the Alarm Notification
section on the Edit MLI Device Properties dialog. Refer to
MLI Device on page 2-36 for more information.
• Interval Select the rate at which you want the monitor to
upload data to the selected destination. Determine the
appropriate interval based on the sample rate for the monitor
and the number of entities for which the monitor records data.
A faster sample rate and/or a greater number of entities may
require a more frequent interval for data delivery.
Note: The remaining parameters apply only when
uploading data to an FTP site.
• Site Enter the address of the FTP site to which you want the
monitor to send the data.
• Folder Enter the name of the folder at the FTP site to which
you want the monitor to upload the data.