Storing a calculated hc value (optional), Storing a calculated hc value ( optional ) – ADS Environmental Services Profile Software 950015B6 User Manual
Page 453

12-20 Profile Software User's Guide
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 - 2012 ADS LLC. All Rights Reserved.
3. Select one or both of the following:
Select the Display checkbox in the Current section of the
tab to display a Manning scattergraph curve based on the
most current HC value in the database (select this option
only if there is a valid HC value in the Current section).
The Current section displays the current hydraulic
coefficient as stored in the database for the Y axis data
entity.
Select the Generate and Display checkboxes in the
Calculated section of the tab to generate and display
Manning's curve based on the current scattergraph data.
4. Select OK to generate the curve(s).
Storing a Calculated HC Value (optional)
After generating a Calculated Manning scattergraph curve, store
the newly calculated HC value to the database.
Curve
Properties
button
1. Select the Edit > Curve Properties option or the Curve
Properties toolbar button.
2. Select the Manning tab.
3. Review the HC value in the Calculated section of the screen.
4. Select the Store button to save the calculated HC value to the
database. Store allows you to define the time period in which
to begin applying the HC value.