Ultrasonic device (flowshark) – ADS Environmental Services Profile Software 950015B6 User Manual
Page 148
2-108 Profile Software User's Guide
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 – 2012 ADS LLC. All Rights Reserved.
Ultrasonic Device (FlowShark)
Edit the ultrasonic device associated with a FlowShark monitor in
the following way. For instructions on editing the ultrasonic device
parameters for all other monitors, refer to Ultrasonic Device on
page 2-105.
Edit Ultrasonic Device Properties (FlowShark)
• Use Defaults Select this checkbox to apply the default
parameters to the ultrasonic device. Deselect this option to
enable the parameter fields for editing.
• Physical Offset Enter the physical distance between the
face of the ultrasonic depth sensor and the top (crown) of the
pipe.
• Scrubbing Window Enter the allowable difference
between individual ultrasonic pair readings and the average
reading of all the pairs. If any single pair exceeds the
difference, the pair will be flagged and removed from the
calculation. The remaining pairs will be averaged to calculate
the depth readings.
• Temperature Offset This field should not require
modification for the FlowShark monitor. No additional
temperature compensation is necessary.