Generating a bestfit roughness and slope – ADS Environmental Services Profile Software 950015B6 User Manual
Page 246

4-24
Profile Software User's Guide
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 - 2012 ADS LLC. All Rights Reserved.
5. Save the Bestfit HC using the Store button. Refer to Storing
the Coefficients on page 4-26, for more information on how to
save the Bestfit HC to the database.
Generating a Bestfit Roughness and Slope
Curve
Properties
button
Select the Colebrook-White tab, accessed by selecting the Curve
Properties toolbar button (after establishing the parameters on the
Setup tab), to generate a curve for the current confirmation data
based on the Colebrook-White equation.
Curve Properties dialog, Colebrook-White tab
1. Select the Display checkbox in the Current section of the tab
to display the Colebrook-White curve (under the Current
Scattergraph section) based on the most current database
Roughness and Slope values.
2. Select the Generate checkbox in the Calculated section of the
screen to generate a Colebrook-White curve based on the
calculated Roughness and Slope factors for the current
scattergraph data.