• Sample Duration Select the duration of time for the sensor
to fire based on the noise present at the monitoring point.
This interval should increase with elevated noise levels. ADS
recommends restricting the selected interval between 3 and 8
seconds.
• Flow Type Select the option that best reflects the kind of
flow conditions that typically occur at the monitoring point:
Typical Flow exhibits a typical diurnal pattern
Wet/Stagnant Flow remains in the pipe, but moves only
during wet weather events
Usually Dry Pipe typically remains dry, except under
wet weather conditions
• Gain This value, editable through the Quantity Coefficient
Generator, represents the factor applied to raw velocity
readings to determine average velocity for receiving
diagnostic readings and calculating quantity and typical days
in the monitor.