that are low in comparison with confirmation readings. 
Profile defaults to 100. 
• Floor Enter the appropriate value to filter the low-level noise
in the sensor. ADS does not recommend changing this 
number. The zero (default) value allows the sensor to adjust 
automatically with changing noise levels. 
• Max Carrier Select the factor to use in detecting or limiting
zero (0) readings that may occur based on the location 
characteristics and flow conditions. Increasing this value may 
help eliminate erratic readings that produce excessive zeros; 
decreasing this value can help detect authentic zeros. For 
example, ADS recommends selecting 800 for dry weather 
overflows. Profile defaults to 8000. 
• Gain This read-only value represents the factor applied to
raw velocity to determine average velocity when taking 
diagnostic readings and calculating quantity and typical days 
in the monitor. This parameter is editable through the 
Quantity Coefficient Generator. 
• Suppression Select this checkbox to maximize sensor
sensitivity. ADS strongly recommends applying this option. 
It is selected by default. 
• Reverse Select this checkbox to enable the monitor to
properly log reverse flow when it occurs at the monitoring 
point. ADS recommends leaving this option unselected only 
when you anticipate that reverse flows will not occur at the 
monitoring point. Profile defaults to unselected. 
• Hanning Select this checkbox for monitors containing a
velocity board with an EPROM of 6.20 or newer. This option 
is selected by default. 
• Store Data Select this checkbox to ensure the monitor logs
the velocity data. This option is selected by default.