Peak combo sl device – ADS Environmental Services Profile Software 950015B6 User Manual
Page 114
2-74
Profile Software User's Guide
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 – 2012 ADS LLC. All Rights Reserved.
Peak Combo SL Device
Edit the Peak Combo SL 1 (or 2) device associated with a
FlowShark Triton or FlowHawk monitor that represents the upward-
looking ultrasonic depth and velocity sensors in the following way.
The Peak Combo SL device corresponds to the Slimline Peak
Combo Sensor.
The Edit Peak Combo SL 1 (or 2) Parameters consists of three
tabs for editing the individual ultrasonic, velocity, and temperature
parameters. Use these parameters to configure the peak combo SL
sensor device.
The following parameters are located in the Device Parameters
section at the lower portion of the Edit Peak Combo SL 1 (or 2)
Parameters window and are relevant to the physical installation of
the sensor.