Displaying the data quality, Overlaying hydrograph data – ADS Environmental Services Profile Software 950015B6 User Manual
Page 538
Hydrograph Reporter
16-15
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 - 2012 ADS LLC. All Rights Reserved.
Note: Select None from the Average Interval drop-
down list to enable the Questionable Data toolbar button.
Questionable Data is first determined by establishing Tolerances
in the Scattergraph Editor. Any data falling outside the
scattergraph Tolerance range is defined as Questionable Data.
Refer to the Scattergraph Editor, Chapter 12, for more information
on setting up the Questionable Data for the hydrograph.
Displaying the Data Quality
Quality
Range
button
Select the Quality Range toolbar button to display the monitor data
quality statistics on the hydrograph.
As the monitor generates flow data, it assigns each flow data point a
quality statistic between 0% and 100%. When the Quality Range
toolbar button is selected, a multi-colored legend displays on the
hydrograph's Y axis, indicating 10 levels of data quality from 0 to
100%. Low quality (0%) is indicated at the bottom of the legend in
red, and high quality (100%) is indicated at the top of the legend in
green. Each data point on the hydrograph is assigned a quality
percent color corresponding to the legend.
Overlaying Hydrograph Data
Overlay
button
Use the Overlay toolbar button when you have requested more data
than can be displayed on the current hydrograph format and you
want to superimpose the additional data over the first data. For
example, select the Overlay toolbar button when you have
requested 14 days of data, but have selected a 7-day hydrograph
report format. Selecting Overlay superimposes the additional 7
days of data over the first 7 days.