ADS Environmental Services PrimeProbe2 User Manual
Pr im ep ro be 2, Installation do’s and don’ts, Precautions and switch-on of the ads primeprobe2

© 2009 ADS LLC. All Rights Reserved.
QR 775025 A0
The ADS PrimeProbe®2 is a bi-directional insertion flowmeter for use in managing water
distribution systems. It has no moving parts making it reliable and ideal for use over a wide range
of flows. PrimeProbe2 is suitable for use in pipe sizes from 4” to 48” (larger sizes available upon
request).
Q U I C K R E F E R E N C E G U I D E
Precautions and Switch-on of the ADS PrimeProbe2
Safety and Precautions
Please read these instructions carefully as they contain important safety information. PrimeProbe2
must be used for the specified application - improper use or tampering will invalidate the warranty.
ADS is responsible only if used in original product configuration.
The PrimeProbe2 should be installed away from any bends or hydraulic fittings. For best results,
•
it should be installed with at least 25 pipe diameters of straight unrestricted pipe upstream of the
sensor, and 10 pipe diameter downstream of the sensor.
For correct operation, the pipe must be completely full of water. It is not necessary that the
•
probe be installed vertically. But must be installed at 90° to the pipe.
Before inserting the probe, ensure the safety chain is correctly secured at both ends
•
. Pipes are
under pressure - failure to tighten the locking collar and connect the safety chain could cause the
probe to be forced upwards with potential injury to the user.
Important
•
– Fully tighten all screws as water ingress can occur.
Pr
im
eP
ro
be
2
®
Installation Do’s and Don’ts
Vertical installations are
preferable in ascending
flow
For vertical installations
with descending flow
direction, contact ADS
Avoid installation
near curves or hydraulic
accessories
The opening of the ball valve
before tightening the fixing
side screws could cause the
expulsion of the sensor from
the pipeline
Avoid the functioning
with the pipe partially
empty
WARNING!!!
WARNING!!!
During the functioning, the
pipe must be completely full
of liquid, or completely empty
Install the sensor away from
curves and hydraulic
accessories
Before opening the ball valve,
fix the sensor with two side
screws