Current readings – ADS Environmental Services Profile Software 950015B6 User Manual
Page 302
Diagnostics
6-31
CONFIDENTIAL – Covered by ADS Software License Agreement
1998 - 2012 ADS LLC. All Rights Reserved.
Landline Select when the monitor communications will be
performed using landline or serial connections.
The monitor’s communication type is now set to the new selection.
Current Readings
The Diagnostics tool enables you to acquire current readings from
some monitors for battery voltage, rain, analog devices, depth,
velocity, flow quantity, volume, diagnostics, and other devices as
available. Obtain current readings from a monitor in the following
way:
1. Select the Connect button to establish communication with the
monitor.
Profile initiates communication with the monitor and establishes a
connection. Choose the Abort button prior to establishing a
connection to abort the communication attempt.
2. Select Current Readings from the Functions drop-down list, and
then select the Perform button.
The Print Preview dialog displays the current readings from the
selected monitor in printable format.