Connecting to a starfire over ip caster, Ntripconfig (ascii) – NavCom Sapphire Rev.J User Manual
Page 446

Sapphire Technical Reference Manual Rev. J
446
H ................................................ Connecting to a StarFire Over IP Caster
These instructions enable the user to connect to a StarFire Over IP caster provided the receiver is
properly optioned.
NTRIPCONFIG (ASCII)
This command specifies the information the NTRIP client requires to connect to the StarFire
Over IP caster.
Command:
[NTRIPCONFIG] {Caster IP} {Caster port} {Mountpoint} {Username} {Password}
{NMEAGGA} {Autoconnect} {Correction port}
Parameter
Definition
Caster IP
addresses
(Moline Caster):
12.105.121.40
(El Segundo Caster):
64.70.43.42
Caster port
number
2101
Mountpoint
name
There are four server names which correspond to different corrections types at different
rates.
a. SFGNSS.1: CF corrections every 1 second
b. SFGNSS.15: CF corrections every 15 second
c. SFGNSS.60 :CF corrections every 60 second
d. SFGNSSCOMPACT.1: CD/CE corrections every 1 second
The mountpoint name is combined with the caster name in the command line.
Username
Leave blank. Generated by receiver, any entry will be ignored.
Password
Leave blank. Generated by receiver, any entry will be ignored.
NMEAGGA
Send NMEAGGA once, if desired. However, it is not needed.
Autoconnect
Recommended. Use CLIENT instead of OFF to better ensure connection to the receiver
if the unit ever disconnects due to a bad link.
Connection type
Eth/Mobile. Use ETH for SF-3050 ethernet connection or MOBILE for use with a
modem (i.e. SF-3040 via Nautiz controller).
Authentication
method
Receiver will use automatically use DIGEST for StarFire mountpoints regardless of
settings.
Examples:
[NTRIPCONFIG] "12.105.121.40", 2101, "SFGNSS.1", , , OFF, CLIENT, ETH, DIGEST
[NTRIPCONFIG] "64.70.43.42", 2101, "SFGNSS.60", , , OFF, CLIENT, ETH, DIGEST