How to view pump information, How to view pump information -9 – Gasboy CFN III Manager Manual V3.6 User Manual
Page 77
MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010
Page 8-9
Pump Commands
Tank and Pump Commands
How to View Pump Information
The PRINT PUMP or P PU command displays information for each pump. If MPDs are used,
PRINT PUMP displays the information for each hose under each pump. Hose numbers are not
displayed, but the information under each pump is in order by hose number.
PRINT PUMP (P PU)
[P:]* PRINT PUMP
↵
P#
T#
Pr
Pc
Price
Totals
$Total
Rate
Limit
Slow
1
1
1
1
0.799
178.770
181.10
100/$
$30
0.500
2
2
2
0.859
360.716
322.74
Pumping
3
3
3
0.919
740.360
741.94
2
1
1
1
0.799
84.110
66.44
100/$
$30
0.500
Down
2
2
2
0.859
2.140
1.83
3
3
3
0.919
462.540
494.42
3
3
3
3
0.919
353.044
357.14
100/$
$30
0.500
4
4
4
4
1.069
336.634
349.97
100/$
$30
0.500
Pumping
5
1
1
1
0.799
7019.954
6722.35
100/G
$500
0.500
6
2
2
2
0.859
503.411
548.22
100/G
$30
0.500
Pumping
7
3
3
3
0.919
464.840
578.71
100/G
$30
0.500
8
4
4
4
1.069
778.470
804.44
100/G
$30
0.500
========= =========
11284.99
11169.30
[P:]*
Command
Description
P#
The pump number is the number of the pump, dispenser, or MPD (in the above example,
pumps 1 and 2 are MPDs).
—
The hose number is not displayed, but is used to determine the order in which hose
information for an MPD is displayed (pumps 1 and 2 have three hoses). For other pumps
and dispensers, the hose number is 1.
T#
The tank number is the number of the fuel storage tank drawn upon by that hose.
Pr
The product code is the number of the product assigned to the hose with LOAD FUEL. Use
PRINT PRODUCT to view the product names that correspond to the numbers.
Pc
The price code controls what prices will be charged for each method of payment such as
cash or credit. It is the code entered with LOAD FUEL.
Price
The price is the current fallback value assigned to the price code with LOAD PRICE (the
fallback price is defined in this chapter under Price codes).
Totals
The quantity totalizer is the cumulative quantity pumped for the hose. These totalizers will
roll over periodically when all 9s are displayed.
$Totals
The dollar totalizer is the cumulative dollar sales for the hose. Dollar totalizers will also roll
over periodically.
Rate
The pulser rate is the number of pulses produced per unit of measure, such as gallons. It
applies only to fuel products, and is an accurate way of measuring flow. $ means that
dollars are being counted, L means that liters are being counted, and G means that gallons
are being counted.
Limit
The fill limit is the amount automatically requested, unless overridden, when a customer
asks for a fill (the limit assigned to privately issued cards can be different than the hose fill
limit).
Slow
The slow flow cutoff point determines how soon before reaching a limit or preset amount
the slow pump mode is activated. The purpose of slow flow cutoff is to prevent the pump
from coasting past the preset amount or limit. Slow flow cutoff point is always specified in
gallons or liters.