Pc address switch, sc-comm cpu - s2, Jumper settings, Sc-comm cpu board settings – Gasboy CFN III Manager Manual V3.6 User Manual
Page 271
![background image](https://www.manualsdir.com/files/787488/content/doc271.png)
MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010
Page A-3
Jumper Settings
SC III Ports and Switches
PC Address Switch, SC-COMM CPU - S2
On the CPU board, card edge right, the PC address DIP sets where in the PC address space
the dual RAM will occur. The SC-Comm board currently assumes D0000.
Switch
Address
Switch
Address
cl cl cl cl
C0000
op cl cl cl
D6000
cl cl cl op
C3000
op cl cl op
D9000
cl cl op cl
C6000
op cl op cl
DC000
cl cl op op
C7000
op cl op op
DF000
cl op cl cl
CC000
op op cl cl
E0000
cl op cl op
CF000
op op cl op
E3000
cl op op cl
D0000*
op op op cl
E6000
cl op op op
D3000
op op op op
E9000
* The SC-Comm board currently assumes this address.
Jumper Settings
SC-Comm CPU Board Settings
Jumper
Description
Setting
K3
AC power fail sense
1-2-3 to disable*
K4
AC watch dog timer
1-2 to enable*
K5
SC-Comm CPU (testing only)
1-2 to reset
K6
RS-485 loop 1
2-3 for 4 wire*
1-2 for 2 wire
K7
RS-485 loop 2
2-3 for 4 wire
1-2 for 2 wire*
K8
Rx Clock from synchronous modem (DB-25-15)
1-2 to connect
K9
ETC output to synchronous modem (DB-25-24)
1-2 to connect
K10
Tx clock onput from synchronous modem (DB-25-17)
1-2 to connect
K11
EPROM type
2-3 for 27128 or 27256
K12
EPROM type
2-3 for 27128 or 27256
* = default