Cabling and Wiring

Introduction

Cabling and Wiring

Use the following illustration to correctly connect your SC III to the various pieces of
equipment.

Figure 1-5: SC III Connections

W&M Switch (S4)

SC-COMM DIP Switch (S3)

Loop 1 Island RS-485 Port

Loop 2 Island RS-485 Port
Factory Set to 2-Wire for Tokheim DPTS

Loop 3 POS High Speed RS-485 Port

Port 1 Local RS-232

Port 6 RS-232

Port 5 RS-232

Port 4 RS-232

Port 3 RS-232

• Port 1, Local RS-232 - Use cable number C05994, SC III terminal cable assembly.
• Port 2, Ribbon Cable to RS-232 - Use ribbon cable C05554 (currently not used).
• Port 3 - The Tokheim driver has been replaced with the Tokheim PC Interface, which uses

a serial port instead of this one (currently not used).

• Port 4 - RS-232 - Use cable number C05995, SC III modem cable assembly.
• Port 5 - RS-232 - This port is extra and can be used as a modem port or logger printer port.
• Port 6 - This port is extra and can be used as a modem port or logger printer port.

Note: Ports 1, 4, 5, and 6 are interchangeable.

Loops 1, 2, and 3 - use cable number C05670, cable assembly 4 position 1:1 HS/Line - 8 feet.
modular cable.

Complete information on ports and switches can be found in

“SC III Ports and Switches”