Records, Menus, Short and long menus – Gasboy CFN III Manager Manual V3.6 User Manual
Page 143: Records -5, Menus -5, Short and long menus -5

MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010
Page 14-5
Menus
Lookup Program
Require manual #: Indicates whether the card user is required to manually enter a number,
such as a vehicle number; the default is no. If a manual number is required, the Enter
auxiliary number step in the Site Controller’s READER configuration program must be set
to optional. If a manual number is required and the Ask for $ amount field is set to no, set the
Digits in restriction code in SYS_PAR to 1 or 2; if a manual number is required and the Ask
for $ amount field is set to yes, set the Digits in restriction code in SYS_PAR to 2.
Require PIN: Indicates whether the card user is required to enter a Personal Identification
Number; the default is no. If a PIN is required, the Enter PIN step in the Site Controller’s
READER configuration program must be set to optional. If a PIN is required and the Ask for
$ amount field is set to no, set the Digits in restriction code in SYS_PAR to 1 or 2; if a PIN is
required and the Ask for $ amount field is set to yes, set the Digits in restriction code in
SYS_PAR to 2.
Ask for $ amount: Should the customer be asked to enter a dollar amount for fuel to be
purchased; the default is no. If the customer enters an amount, the pump will stop once that
amount has been pumped. The customer can either enter an amount or press FILL. If a
$ amount is required, the Enter amount step in the Site Controller’s READER configuration
program must be set to optional. If a $ amount is required, set the Digits in restriction code in
SYS_PAR to 2.
Records
The Lookup program stores its data in records. Each lookup number and lookup type together
require one record (more than one record can contain the same lookup number, but in that
case, each record will have a different lookup type).
All records have the same number of fields (18 at the time this manual was written), but few, if
any, records will have all fields filled in.
The records are stored in a file named LOOKUP.DTA.
Menus
You call up the Lookup program by typing LOOKUP at the system prompt [P:]* and press
Enter. You run the Lookup program through a series of menus and submenus.
Note: The menus in this chapter are shown as they initially appear on the screen, where one
field (usually the first) is automatically selected. However, as you select other fields, the
instructions at the bottom of the menu change, depending on which field is selected.
Short and Long Menus
Most menus are one of two types: short or long. A short menu lets you enter only a lookup
number and, optionally, a lookup type.
Once you enter the lookup number (and lookup type) on a short menu, a long menu is
displayed that contains all fields. You can then add or delete records, edit fields, and so on.