Card: xxxxxxxxxx des not ready, Diagnostics table too small, Disk full – Gasboy CFN III Manager Manual V3.6 User Manual
Page 288: Emergency stop, End emergency stop, Fuel point reader # on loop # went down, Fuel point reader # came up, Gate # on loop # went down

Status and Error Messages
Messages on the Log Printer
Page D-6 MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010
CARD: XXXXXXXXXX DES Not Ready
DES (data encryption standard) encryption unit in a card reader was not ready to process a
bank card, probably because one of the two keys was not loaded.
Contact your bank network representative.
Diagnostics Table Too Small
Not enough available records in the diagnostic table.
The size of the diagnostic table is set in the SC III configuration.
If this message occurs at startup, you will require to configure for a larger diagnostic table
size.
Disk Full
The RAM disk is full.
Delete unnecessary files from the disk.
EMERGENCY STOP
An ALL stop has been done from the POS console, or a STOP; a command was issued.
No action is required. Press the ALL STOP key on the console again when all is secure to
end the emergency stop, or issue a RUN;A command from the terminal keyboard.
End EMERGENCY STOP
ALL stop done from the console is no longer in effect.
No action is required.
Fuel Point Reader # on Loop # Went Down
A Fuel Point Reader has gone down.
Check reader.
Fuel Point Reader # Came Up
A Fuel Point Reader has come back online.
No action is required.
Gate # on Loop # Went Down
A Gate has gone down.
Check gate.