Page 26-5
Site Devices
Enabling and Disabling Devices
How to Disable and Enable a Pump Control Unit
Use the command DISABLE PCU or DI PC to shut down a pump control unit (PCU).
DISABLE PCU (DI PC)
[P:]* DISABLE PCU
↵
PCU number? 2
↵
[P:]*
ENABLE PCU (E PC)
[P:]* ENABLE PCU
↵
PCU number? 2
↵
[P:]*
Use the command ENABLE PCU or E PC to return a pump control unit to operation.
ENABLE PCU with the I option (ENABLE PCU;I) enables all pump control units.
How to Disable and Enable a Reader Terminal
Use the command DISABLE READER or DI RE to shut down an island card reader (ICR).
DISABLE READER (DI RE)
[P:]* DISABLE READER
↵
Reader number? 1
↵
[P:]*
ENABLE READER (E RE)
[P:]* ENABLE READER
↵
Reader number? 1
↵
[P:]*
Use the command ENABLE READER or E RE to return an ICR to operation.
ENABLE READER with the I option (ENABLE READER;I) enables all ICRs.