Status and Error Messages

Messages on the Log Printer

Page D-8 MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010

If your site is not connected to a host site or polled by a remote computer, then print
transactions in memory using the command PRINT TRANSACTIONS, or transfer them to
your billing computer, according to your usual procedure.

After the transactions are securely recorded for billing or accounting purposes, use the
command RESET TRANSACTION to make room in memory for additional transactions.

XPE PC-SCIII Interface V#.# Started

Boot message that the SC#.EXE interface program has started.

PC Not Responding

The site is running but not getting a response from the PC through the SC3.EXE program.
Check the PC. May see this on startup. Site must still open.

PC Responding

Site is communicating with the PC.

No action is required.

Product #XX Name Below Reorder Level

The product inventory of the indicated product is below the reorder level configured with the
LOAD INVENTORY command.

Follow your company’s procedures for reordering products.

Pump #X Disabled

The indicated pump has been disabled by the command DISABLE PUMP.

No action is required. Return the pump to operation with the command ENABLE PUMP
when appropriate.

Pump #X Disabled, No Quantity

The indicated pump has been disabled because the SC III has received too many

zero-quantity transactions from that pump.

A zero-quantity transaction is one in which the pump is activated but no fuel is pumped. The
SC III will automatically disable any pump that exceeds a certain number (set in SYS_PAR)
of zero-quantity transactions. This is a precaution against pump pulser (flow sensor) or pulser
cable failure.

Check the pump no-quantity transaction (NQN) count in the diagnostics printout, using the
command PRINT DIAGNOSTICS 8. If there are several NQNs, try to determine the cause or
consult your service representative.

If a pulser unit or attached cables have failed, fuel can flow until the pump times out, but no
gallons or dollars will be recorded.