MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010

Page D-7

Messages on the Log Printer

Status and Error Messages

Gate # Came Up

A Gate has come back online.

No action is required.

Island EMERGENCY STOP

The DISABLE PUMP button on the island has been pressed, or a communications problem
has developed on the RS-422 loop to the island.

To end an island emergency stop, enter a RUN;A command from the terminal keyboard, or
press the ALL STOP key on the console twice.

If the island button was not pressed (or does not exist), contact your service representative.

Island Reader Only

Displays when you try to use Fueler ID, Supervisor cards, Fuel Drop cards, Dipstick cards
and Fueler cards at the Console. These can only be used at the Island Reader.

Loop Table Overflow

There can be 64 loop devices.

If there are more than 64 loop devices, this error occurs.

Loop devices are consoles, island card readers, pump control units, electronic pumps, MPDs,
and so on.

If you do not have more than 64 loop devices and experience this error, contact your service
representative.

Master Key Loaded

DES decryption master key is present.

No action is required.

Memory Available

Memory is available for new transaction records.

Memory Full

There is no room in memory for additional transactions.

The SC III will not accept new transactions.

If your site is connected to a host site, contact your system administrator.