How to reset system diagnostics, Diagnostic error codes – Gasboy CFN III Manager Manual V3.6 User Manual

Page 242

background image

[P:]* PRINT DIAGNOSTICS 3

D I A G N O S T I C S

Island Card Reader # 1 on loop 1 came up Mon 5/10/04 12.18 PM
Printer/PINpad #3 on loop 3 came up Mon 5/10/04 12.18 PM
Printer/PINpad #10 on loop 3 came up Mon 5/10/04 12.18 PM
[P:]*

Diagnostic Commands

System Diagnostics

Page 25-2 MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010

You may use numerical options with the command PRINT DIAGNOSTICS to print the
diagnostics for specified types of devices.

The device type numbers are:

0 = when diagnostics were last reset
1 = site information
2 = PCUs
3 = readers
4 = consoles
5 = fuel point readers
6 = gate controllers
7 = tank gauges
8 = pumps
12 = SDI

How to Reset System Diagnostics

Use RESET DIAGNOSTICS or RE DI to set the diagnostic error totals to zero. Reset the
diagnostics monthly after you print the current diagnostics with PRINT DIAGNOSTICS. This
will maintain a current error diagnosis.

RESET DIAGNOSTICS (RE DI)

[P:]* RESET DIAGNOSTICS

[P:]*

How to Reset System Diagnostics after Reconfiguration

RESET DIAGNOSTICS without any options just clears the counters for existing diagnostics
records. RESET DIAGNOSTICS with the I option removes all the diagnostic records and

re-creates records for the current configuration.

You can use RESET DIAGNOSTICS;I to delete the diagnostics records for the non-existent
devices. This can be useful if you reconfigure the site to have fewer of some type of device.
After you reconfigure the site, diagnostic records will still exist for the devices that have been
removed.

Diagnostic Error Codes

You may use the A option with PRINT DIAGNOSTICS. The following error codes may
appear in response to PRINT DIAGNOSTICS;A.