MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010

Page 25-11

How to Test a Pump Control Unit’s Memory

Diagnostic Commands

How to Test a Pump Control Unit’s Memory

Use the command TEST PCU or TE PC to test the RAM and ROM of a pump control unit.
The test checks the transaction and program memory. If the pump control unit does not pass
the test, an error message is printed. If it does pass the test, no message is displayed.

TEST PCU (TE PC)

[P:]* TEST PCU

PCU address? 1

[P:]*

How to Test a Receipt Printer

You can use the command PRINT RECEIPT or P REC to print any text on a console or island
card reader receipt printer. This is a handy way to test the receipt printer without having to
print a receipt.

PRINT RECEIPT (P REC)

[P:]* PRINT RECEIPT

Printer number? 1

Line to print? GASBOY CFN

[P:]*

(Refer to

“Making Your Own Commands”

on

page 19-1

).

For receipt printers on island card readers, the printer number is the number of the island card
reader. Line to print is the text you want printed on the receipt printer.

SHOW Command

SHow: Designed to display communication between the site and devices. Displays
communication for chosen devices when there is a change. The devices chosen must be up in
order to be displayed. The syntax for the command is:

SHow [ ...]

A device is a device name followed by a space and either a device number or an asterisk (*)
indicating all of that device. The valid devices are: REader, COnsole, GAte, TMs, FPr, SDI,
PUmp Pcu, and LOOP.

Additionally, a device may be a single word if it is one of the following:

ALL - Shows communication for all devices.
RBroad - Shows reader broadcast messages.
CBroad - Shows console broadcast messages.
ROUTer - Shows router activity.

Communication will continue to be displayed until ^C (control key -C) is typed.
Communication errors such as failure to respond or CRC errors are indicated. It must be noted
that since this display function is being handled at a relatively high level within the software,
partial responses from a device will appear to be a non-response.