How to restart a site from a serious crash, How to reboot the site controller, Caution – Gasboy CFN III Manager Manual V3.6 User Manual
Page 255
![background image](https://www.manualsdir.com/files/787488/content/doc255.png)
MDE-4871 CFN III Manager’s Manual for Windows® XP Embedded - Version 3.6 · August 2010
Page 26-3
Shut Down and Restart a Site
Enabling and Disabling Devices
How to Restart a Site from a Serious Crash
Do not use the command RUN;I to restart the site after a crash without first
consulting with your service representative. If the problem that caused the crash is
not fixed before the Site Controller is restarted, damage could result.
CAUTION
[P:]* RUN;I
↵
Verify (y/n)? y
↵
[P:]*
Use the command RUN;I to restart the site after a crash. A crash can be caused by a system
error, file error, or some other problem. RUN;I will restart the site even after a serious crash.
The plain RUN command will restart the site after mild crashes.
How to Reboot the Site Controller
Use the command REBOOT to reboot the Site Controller. REBOOT with the A option causes
the Site Controller to reboot from disk. That is how you load a new version of the software. It
is a good idea to use the command STOP to shut down the site before you reboot.
REBOOT
[P:]* STOP
↵
Verify (y/n)? y
↵
[P:]* REBOOT
↵
Verify (y/n)? y
↵
[P:]*
There are various types of reboots.
REBOOT
The plain REBOOT command reboots the Site Controller and reloads the configuration from
the disk. The file FRAMOS.CFG must be in the root directory of the default drive.
Use this command to load a new configuration.
REBOOT;I
With the I option, REBOOT reboots the Site Controller but does not load a new configuration.
Instead, the former configuration is used.
Use this command to reboot the Site Controller when the configuration file is not available.
REBOOT;A
With the A option, REBOOT reboots the Site Controller and loads the operating system off
disk. The files FRAMOS.BIN and FRAMOS.CFG must be in the root directory of the default
drive.