Z8018x

Family MPU User Manual

UM005003-0703

67

vector table can be relocated on 32 byte boundaries. IL is initialized to

00H

during RESET.

INT/TRAP Control Register (ITC)

ITC is used to handle TRAP interrupts and to enable or disable the
external maskable interrupt inputs INT0, INT1 and INT2.

Interrupt Vector Low Register (IL: 33H)

Bit

7

6

5

4

3

2

1

0

Bit/Field

IL7

IL6

IL5

?

R/W

R/W

R/W

R/W

?

Reset

00H 00H 00H

?

Note: R = Read W = Write X = Indeterminate ? = Not Applicable

Bit
Position

Bit/Field

R/W

Value Description

7

5

IL7

5

R/W

The IL register is an internal I/O register which is
programmed with the OUT0 instruction and can be read
using the IN0 instruction.

4

0

?

N/A

Interrupt source dependent code