2

0

MOD2

0 R/W

ASCI Data Format Mode 2, 1, 0 — These bits program
the ASCI data format as follows.

MOD2
0: 7 bit data
1: 8 bit data

MOD1
0: No parity
1: Parity enabled

MOD0
0: 1 stop bit
1: 2 stop bits

The data formats available based on all combinations of
MOD2, MOD1 and MOD0 are described in Table 17.

Bit
Position Bit/Field R/W

Value

Description