PRT Operation Notes

TMDR data is accurately read without stopping down counting by
reading the lower (TMDRnL*) and higher (TMDRnH*) bytes in that
order. Also, TMDR is read or written by stopping the down
counting.

1

Take care to ensure that a timer reload does not occur during or
between lower (RLDRnL*) and higher (RLDRnH*) byte writes. This
may be guaranteed by system design/timing or by stopping down
counting (with TMDR containing a non-zero value) during the RLDR
updating. Similarly, in applications where TMDR is written at each
TMDR overflow, the system/software design must guarantee that
RLDR can be updated before the next overflow occurs. Otherwise,
time base inaccuracy occurs.

During RESET, the multiplexed A18/TOUT pin reverts to the address
output. By reprogramming the TOC1 and TOC0 bits, the timer output
function for PRT channel 1 is selected. The following paragraph
describes the initial state of the TOUT pin after TOC1 and TOC0 are
programmed to select the PRT channel 1 timer output function.

PRT (channel 1) has not counted down to 0.

If the PRT has not counted down to 0 (timed out), the initial state of
TOUT depends on the programmed value in TOC1 and TOC0.

Secondary Bus Interface

E clock Output Timing

The Z8X180 also has a secondary bus interface that allows it to easily
interface with other peripheral families.