AT-S62 Menus Interface User’s Guide

Section II: Advanced Operations

215

For example, selecting LOCAL2 as the facility level assigns the
numerical code of 18 to all events sent to the syslog server by the
switch.

6 - Event Severity
The severity of events to be sent by the switch to the syslog server.
Event severity is a predefined value assigned to an event by the
switch according to its potential impact on the switch’s operation.
You can use this parameter to configure the switch to send only
those events that match one or more severity levels. There are
four severity levels, as defined in Table 3 on page 205. The default
is informational, error, and warning. You can specify more than
one severity level (for example, E,W).

7 - Event Module
The originating module of the events to be sent to the syslog
server. The AT-S62 management software consists of a number of
modules, each responsible for a different part of switch operation.
You can use this parameter to instruct the switch to send only
those events that originated from selected modules. The default
is ALL, which sends the events from all modules. The modules are
defined in Table 4 on page 206. You can specify more than one
module (for example, CLI,MAC,STP).

7. After you have configured the syslog server definition, type C to

select Create Log Output.

18

LOCAL2

19

LOCAL3

20

LOCAL4

21

LOCAL5

22

LOCAL6

23

LOCAL7

Table 6 Numerical Code and Facility Level Mappings

Numerical
Code

Facility Level Setting