Tally generation settings, Deleting wiring settings sorting wiring settings, Deleting wiring settings – Sony GP-X1EM Grip Extension User Manual
Page 490: Sorting wiring settings, Configuring tally generation, Modifying tally generation
490
3
Press [Execute].
Deleting Wiring Settings
1
In the Engineering Setup >Router/Tally >Wiring
menu (7363), select the wiring.
2
Press [Delete].
Sorting Wiring Settings
In the Engineering Setup >Router/Tally >Wiring menu
(7363), press [Sort].
The sorting of wiring settings is executed in the following
sequence.
Destination level order (ascending)
t
Destination
address order (ascending)
t
Source level order
(ascending)
Tally Generation Settings
Specify the destination to be the reference for tally
generation, and configure the settings.
The settings used are common to both parallel and serial
tallies.
Configuring Tally Generation
1
In the Engineering Setup >Router/Tally >Tally Enable
menu (7364), press [New].
The New menu (7364.1) appears.
2
Set the following parameters.
a) 1, 3, 5, 7, 9, 11, 13, 15: R1 to R8 (red tally)
2, 4, 6, 8, 10, 12, 14, 16: G1 to G8 (green tally)
17 to 24: Y1 to Y8 (yellow tally, NS-Bus only)
3
In the
generation mode.
Enable:
Always generate a tally.
Disable:
Never generate a tally.
Tally Input:
Generate a tally from the tally input state.
4
When [Tally Input] is selected in step
3
, select one of
the following in the
DCU1:
Generate tally with reference to signal that is
input on the SIU1 (DCU function) port.
DCU2:
Generate tally with reference to signal that is
input on the SIU2 (DCU function) port.
Select the tally input port number using the following
parameter.
5
Press [Execute].
Modifying Tally Generation
1
In the Engineering Setup >Router/Tally >Tally Enable
menu (7364), press [Modify].
No.
Parameter
Adjustment
1
Destination
(Address)
Destination address
2
Destination
(Level)
Destination level
3
Source
(Address)
Source address
4
Source
(Level)
Source level
No.
Parameter
Adjustment
1
Destination
Address
Destination address
2
Destination
Level
Destination level
3
Tally Type
Tally type
a)
No.
Parameter
Adjustment
5
Input Port
Tally input port number