Metrohm 726 Titroprocessor User Manual
Page 93
5. Methods and determinations
726 Titroprocessor, Instructions for use
87
87
The main page of the Titroprocessor 726 should be similar to that shown
below:
[Sample silo]
•
To enter the sample data open the sample silo with the [Sample
silo]
softkey.
ЪДДД Sample silo : NEW.slo ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД¿
³ ³
³ # Method Ident1 Ident2 Ident3 Size Unit ³
³ ДДД ДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДД ДДДДД ³
³ <> 1 ³
³ 2 ³
³ 3 ³
•
Now enter the sample data line by line. This can be done manually or
the sample weight can be transferred directly from a balance. In the
latter case the sample identifiers can be entered later by hand.
•
If the necessary method has already been loaded then leave the
'Method' column empty. An entry would have the effect that before the
silo line involved is processed the given method is loaded into the
working memory.
•
Further details about editing the sample silo can be found on page 92ff.
•
In order to indicate which sample should be processed place the field
cursor on the line containing the sample data of the first sample. Press
the [ >> >> ] softkey to display the second softkey bar. Use the
[<-- Out pointer]
softkey to set the silo output marker. This
always marks the next silo line to be processed with the '<' character. It
is carried out again for each determination.
³ # Method Ident1 Ident2 Ident3 Size Unit ³
³ ДДД ДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДДДДД ДДДДДДДДД ДДДДД ³
³ < 1 971120/1 12 3455 100 mL ³
³ 2 971120/1 12 3455 100 mL ³
³ 3 971120/2 15 3455 100 mL ³
1997-11-27 10:17:52 MAIN PAGE 726 Titroprocessor * ready *
Method 3455.mth Chloride in Tap Water
ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД
ЪДДДДДДДДДД Application Note ДДДДДДДДДДДДДДД¿
User B. Miller ³ Chloride in Tap Water ³
Run number 000 ³ ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД³
Statistics on 0 of 10 ³ ³
³ ³
Auto save on 78.7 % free ³ Pipet 100.00 mL tap water exactly in a ³
Destination Data card ³ 150 mL beaker. ³
Determ.name ³ ³
³ ³
Auto start on 0 of 10 ³ ³
Silo on in# 11 out# 1 ³ ³
Changer 1 Sample pos. 1 ³ ³
АДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДЩ
Ident1 Ident2 Ident3 Size Unit
Sample
Remark
ЪДДДДДДДДДДДДДДДДДДДДДДД¿ ЪДДДДДДДДДДДДДДДДДДДДДДД¿ ЪДДДДДДДДДДДДДДДДДДДДДДД¿
³Config.³Load ³File ³ ³Edit ³Show ³Results³ ³Sample ³Devices³Common ³
³ ³method ³manager³ ³method ³curves ³ ³ ³silo ³ManCtrl³vars ³
АДДДДДДДДДДДДДДДДДДДДДДДЩ АДДДДДДДДДДДДДДДДДДДДДДДЩ АДДДДДДДДДДДДДДДДДДДДДДДЩ