beautypg.com

Metrohm 726 Titroprocessor User Manual

Page 199

background image

8. Command reference

8. Command reference

726 Titroprocessor, Instructions for use

193

193

ADD_R

Adding a relative volume

The ADD_R command allows a calculated volume of auxiliary reagent to be
added at any time during a method run. The volume is calculated from the

sample weight with the aid of a factor.

Command Parameters Parameters

ДДДДДДДДДДДДД ДДДДДДДДДДДДДДДДДДДДДДДД ДДДДДДДДДДДДДДДДДДДДДДДД

ADD_R

Reagent Dos. drive A1

concentr. Dos. rate max mL/min

Factor 0.0 Fill. rate max mL/min

The parameters of the ADD_R command largely corre-
spond to those of the ADD_A command. Only a calcula-
tion factor is entered instead of the absolute volume.

Factor

Calculation factor

-99999.0…

0.0…99999.0

The effective value of the relative reagent volume is cal-

culated from:

Volume in mL = Sample size

∗∗ factor

.

The maximum reagent volume which can be added is

1000 mL. If a larger value is obtained from the calculation

then the reagent volume will be automatically reduced to

1000 mL.

The other parameters correspond to those of the ADD_A command, see

page191.

PREP

Preparing a buret unit

The preparation, i.e. the rinsing of a buret unit cannot only be carried out

manually, but can also be programmed in a method, preferably in a start

sequence (OMOVE) which is carried out once. The necessary rinsing volume
is calculated from the dimensions of the dosing and filling tubing of the ex-

change unit or dosing unit used.

Command Parameters Parameters

ДДДДДДДДДДДДД ДДДДДДДДДДДДДДДДДДДДДДДД ДДДДДДДДДДДДДДДДДДДДДДДД

PREP

Tubing Default Dos. drive A1

Tubing

Name of type of buret unit

8 characters

The type of buret unit defines the tubing parameters and

other settings which are necessary for the correct prepa-

ration of the buret unit. The definition of the various types

is carried out in the configuration under 'Tubings'. The
entry field contains a selection list with the different types

of dosing drive.