Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual
Page 89

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
89
Connecting the Kinetix 6000 Drive System
Chapter 5
3. Move the ground jumper.
4. Replace the IAM module front panel and two screws.
Apply 1.6 N•m (14 lb•in) torque.
5. Mount the IAM module back on the power rail.
Refer to Replace Kinetix 6000 Drive Modules on
.
IAM Module (series A)
Configuration
Grounded (default)
Ungrounded
2094-ACxx-Mxx-x (230V)
(1)
(1) Applies to series A and C (230V) drives.
P15 and P16
P15 and P17
2094-BC01-MP5-x (460V)
P13 and P14
P13 and P12
2094-BC01-M01-x (460V)
2094-BC02-M02-x (460V)
2094-BC04-M03-x (460V)
P14 and P13
P14 and P12
2094-BC07-M05-x (460V)
IAM Module (series B and C)
Configuration
Grounded (default)
Ungrounded
2094-BC01-MP5-S (460V)
P16 and P17
P18 and P19
2094-BC01-M01-S (460V)
2094-BC02-M02-S (460V)
2094-BC04-M03-S (460V)
2094-BC07-M05-S (460V)