Motor Feedback Connector Pinout
Table 26 - Stegmann Hiperface (SRS/SRM)
Table 27 - TTL or Sine/Cosine with Index Pulse and Hall Commutation
Table 28 - Resolver Transmitter (transformation ratio = 0.25)
MF Pin
Description
Signal
MF Pin
Description
Signal
1
Sine differential input+
SIN+
9
Reserved
–
2
Sine differential input-
SIN-
10
Hiperface data channel
DATA-
3
Cosine differential input+
COS+
11
Motor thermal switch (normally closed)
(1)
TS+
4
Cosine differential input-
COS-
12
Reserved
–
5
Hiperface data channel
DATA+
13
Reserved
–
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V
(2)
7
Encoder power (+9V)
EPWR_9V
(2)
15
Reserved
–
8
Reserved
–
(1) Not applicable unless motor has integrated thermal protection.
Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.
(2) Encoder power supply uses either 5V or 9V DC based on encoder/motor used.
MF Pin
Description
Signal
MF Pin
Description
Signal
1
AM+ / Sine differential input+
AM+ / SIN+
9
Reserved
–
2
AM- / Sine differential input-
AM- / SIN-
10
Index pulse-
IM-
3
BM+ / Cosine differential input+
BM+ / COS+
11
Motor thermal switch (normally closed)
(1)
TS+
4
BM- / Cosine differential input-
BM- / COS-
12
Single-ended 5V hall effect commutation
S1
5
Index pulse+
IM+
13
Single-ended 5V hall effect commutation
S2
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V
(2)
7
Encoder power (+9V)
EPWR_9V
(2)
15
Reserved
–
8
Single-ended 5V hall effect commutation
S3
(1) Not applicable unless motor has integrated thermal protection.
Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.
(2) Encoder power supply uses either 5V or 9V DC based on encoder/motor used.
MF Pin
Description
Signal
MF Pin
Description
Signal
1
Sine differential input+
S2
9
Reserved
–
2
Sine differential input-
S4
10
Resolver excitation
R2
3
Cosine differential input+
S1
11
Motor thermal switch (normally closed)
(1) (2)
TS+
4
Cosine differential input-
S3
12
Reserved
–
5
Resolver excitation
R1
13
Reserved
–
6
Common
ECOM
14
Reserved
–
7
Reserved
–
15
Reserved
–
8
Reserved
–
(1) Not applicable unless motor has integrated thermal protection.
Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.
(2) If using 1326AB (resolver-based) motors, use 2090-K6CK-D15MF Low-profile Connector Kits that connect the filtered thermal switch (pins 16 and 17) to MF-11 and MF-6.