Connect panel-mounted breakout board kits, Connect panel-mounted breakout board kits on – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual
Page 121
Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
121
Connecting the Kinetix 6000 Drive System
Chapter 5
Connect Panel-mounted Breakout Board Kits
The 2090-UXBK-D15
xx panel-mounted breakout board kit includes a DIN-rail
breakout board and cable. The cable connects between the breakout board and
the motor feedback (MF) connector. Wires from your flying-lead motor
feedback cable connect to the terminals.
Figure 63 - IAM/AM Module (MF connector)
2090-UXBC-D15xx
Breakout Cable
2090-UXBB-D15
Panel-mounted Breakout Board
Wire Terminations
Motor Feedback (MF) Connector
Kinetix 6000, Front View
(IAM module is shown)
Kinetix 6000, Side View
(IAM module is shown)
Refer to CN2 Motor Feedback Breakout Board
Installation Instructions, publicatio
, for
connector breakout board specifications.
IMPORTANT
The panel-mounted breakout board kit (2090-UXBK-D15xx) is not compatible
with 1326-CCUT-L-xxx cable.