background image

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013

121

Connecting the Kinetix 6000 Drive System

Chapter 5

Connect Panel-mounted Breakout Board Kits

The 2090-UXBK-D15

xx panel-mounted breakout board kit includes a DIN-rail

breakout board and cable. The cable connects between the breakout board and
the motor feedback (MF) connector. Wires from your flying-lead motor
feedback cable connect to the terminals.

Figure 63 - IAM/AM Module (MF connector)

2090-UXBC-D15xx
Breakout Cable

2090-UXBB-D15

Panel-mounted Breakout Board

Wire Terminations

Motor Feedback (MF) Connector

Kinetix 6000, Front View

(IAM module is shown)

Kinetix 6000, Side View
(IAM module is shown)

Refer to CN2 Motor Feedback Breakout Board

Installation Instructions, publication

2090-IN006

, for

connector breakout board specifications.

IMPORTANT

The panel-mounted breakout board kit (2090-UXBK-D15xx) is not compatible
with 1326-CCUT-L-xxx cable.