Planning the Kinetix 6000 Drive System Installation
In this example, the enclosure must have an exterior surface of 6.66 m
2
. If any
portion of the enclosure is not able to transfer heat, do not include that portion
in the calculation.
Because the minimum cabinet depth to house the 460V drive (selected for this
example) is 302 mm (11.9 in.), then the cabinet needs to be approximately 2500
mm (high) x 950 mm (wide) x 302 mm (deep).
2 x (0.3 x 0.95) + 2 x (0.3 x 2.5) + 2 x (0.95 x 2.5) = 6.82 m
2
Because this cabinet size is considerably larger than what is necessary to house the
system components, consider some means of cooling in a smaller cabinet to be
more efficient. Contact your cabinet manufacturer for options available to cool
your cabinet.
Table 12 - Power Dissipation Specifications
Bulletin 2094 Drive Modules
(1)
Usage as % of Rated Power Output
(watts)
20%
40%
60%
80%
100%
IAM (converter) module
(2)
2094-AC05-MP5-S
8
11
15
19
24
2094-AC05-M01-S
9
12
16
20
25
2094-AC09-M02-S
14
20
28
36
46
2094-AC16-M03-S
19
30
43
58
74
2094-AC32-M05-S
41
68
100
136
176
2094-BC01-MP5-S
18
21
25
29
34
2094-BC01-M01-S
33
2094-BC02-M02-S
36
44
54
64
75
2094-BC04-M03-S
50
67
87
110
135
2094-BC07-M05-SS
71
101
137
179
226
IAM (inverter) module or AM module
2094-AC05-MP5-S or 2094-AMP5-S
28
32
37
41
46
2094-AC05-M01-S or 2094-AM01-S
31
38
46
54
62
2094-AC09-M02-S or 2094-AM02-S
34
45
57
70
84
2094-AC16-M03-S or 2094-AM03-S
48
68
91
116
144
2094-AC32-M05-S or 2094-AM05-S
104
156
212
274
342
2094-BC01-MP5-S or 2094-BMP5-S
46
54
61
69
77
2094-BC01-M01-S or 2094-BM01-S
57
73
90
108
126
2094-BC02-M02-S or 2094-BM02-S
53
72
93
116
142
2094-BC04-M03-S or 2094-BM03-S
94
130
169
211
255
2094-BC07-M05-S or 2094-BM05-S
121
183
252
326
407
Shunt module - 2094-BSP2
68
121
174
227
280
IPIM module - 2094-SEPM-B24-S
To calculate power dissipation for IPIM modules on your 2094 power rail, refer to the Kinetix 6000M Integrated Drive-Motor User
Manual, publicat
(1) Power dissipation for the Bulletin 2094 control modules, catalog numbers 2094-SE02F-M00-Sx and 2094-EN02D-M01-Sx, is included in the IAM and AM power module specifications.
(2) Internal shunt power is not included in the calculations and must be added based on utilization.