Analog outputs – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual
Page 69

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
69
Connector Data and Feature Descriptions
Chapter 4
Analog Outputs
The IAM and AM modules include two analog outputs (IOD-23 and IOD-25)
that you can configure through software to represent drive variables.
Figure 31 - Analog Output Circuit
Table 39 - Analog Output Specifications
Table 40 - Linear Scaling Specifications
For configuration/set up of the analog outputs, refer to Configure Drive
Parameters and System Variables beginning on
CH1
CH1
CH2
CH2
DAC
Oscilloscope
Kinetix 6000 IAM/AM
Module
(second channel not shown)
IMPORTANT
Output values can vary during powerup until the specified power supply
voltage is reached.
Parameter
Description
Min
Max
Resolution
Number of states that the output signal is divided into, which
is 2
(to the number of bits)
.
–
±11 bits
Output current
Current capability of the output.
0
+2 mA
Output signal
range
Range of the output voltage.
2094-xCxx-Mxx and
2094-xMxx drives
0
+5V
2094-xCxx-Mxx-S
and 2094-xMxx-S
drives
0
+10V
Offset error
Deviation when the output is expected to be at 0V.
–
1 mV
Bandwidth
Frequency response of the analog output
DC
7.2k Hz (3 db)
Drive Cat. No.
Speed
rpm
Value
V DC
Torque
%
2094-xCxx-Mxx
or 2094-xMxx
10,000
5.0
1000
0
2.5
0
-10,000
0
-1000
2094-xCxx-Mxx-S
or 2094-xMxx-S
10,000
10.0
1000
0
5.0
0
-10,000
0
-1000