Mounting the Kinetix 6000 Drive System
Chapter 3
4. Pivot module downward and align the guide pins on the power rail with
the guide pin holes in the back of the module.
5. Gently push the module against the power rail connectors and into the
final mounting position.
Guide Pin
Holes
Power rail (side view)
in upright vertical position.
Guide Pins
Pivot module downward
and align with guide pins.
Kinetix 6000 IAM, AM, IPIM, Shunt,
or Slot-filler Module, Side View
(IAM module is shown)
Kinetix 6000 IAM, AM, IPIM, Shunt,
or Slot-filler Module, Rear View
(IAM module is shown)
TIP
The IAM module can have two or three power rail connectors and guide pins,
the AM module can have one or two, all other modules have one.