Calculate additional bus capacitance, Bulletin 2094 drive capacitance values – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual
Page 227
Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
227
DC Common Bus Applications
Appendix C
Calculate Additional Bus
Capacitance
Additional bus capacitance is the sum of all follower IAM, AM, and IPIM
module capacitance values for your Bulletin 2094 common-bus modules.
Specifically, this includes the capacitance values for each of these modules:
• Each follower IAM (converter and inverter) module
• Each AM module on the follower IAM module power rail
• Each IPIM module on the follower IAM module power rail
Enter the additional bus capacitance value in Set the Additional Bus Capacitance
Parameter beginning on
Bulletin 2094 Drive
Capacitance Values
Use these tables when calculating total bus capacitance and additional bus
capacitance for your Bulletin 2094 common-bus application.
Table 117 - IAM/AM (200V-class) Modules
Table 118 - IAM/AM (400V-class) Modules
Table 119 - Shunt Module (200/400V-class)
Table 120 - IPIM Module (400V-class)
IAM Converter (200V-class)
Capacitance
μF
AM Inverter (200V-class)
Capacitance
μF
2094-AC05-MP5-x
270
2094-AMP5-x
390
2094-AC05-M01-x
2094-AM01-x
660
2094-AC09-M02-x
540
2094-AM02-x
780
2094-AC16-M03-x
1320
2094-AM03-x
1320
2094-AC32-M05-x
1980
2094-AM05-x
2640
IAM Converter (400V-class)
Capacitance
μF
AM Inverter (400V-class)
Capacitance
μF
2094-BC01-MP5-x
110
2094-BMP5-x
75
2094-BC01-M01-x
2094-BM01-x
150
2094-BC02-M02-x
220
2094-BM02-x
270
2094-BC04-M03-x
940
2094-BM03-x
840
2094-BC07-M05-x
1410
2094-BM05-x
1175
Shunt Module
(200/400V-class)
Capacitance
μF
2094-BSP2
470
IPIM Module (400V-class)
Capacitance
μF
2094-SEPM-B24-S
840