Driveexplorer software – Rockwell Automation 2094-xMxx-S Kinetix 6000 Multi-axis Servo Drives User Manual User Manual
Page 263

Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
263
Enhanced Peak Performance
Appendix F
3. Verify change with another sercos IDN Read Message from IDN P:0:7
and examine bit zero.
Refer to this Logix Designer application example.
DriveExplorer Software
To use DriveExplorer software to change IDN parameter values, you must also
have the 1203-SSS Serial to SCANport adapter. Refer to
for more information on changing IDN parameter values by using this
method.
1. Connect a 1203-SSS Serial to SCANport adaptor to the drive by using
DriveExplorer software.
2. Change parameter P507 [Drv Peak Rating] from 150% to 250% (or 200%
if applicable).
3. Save device values to nonvolatile memory.