Rockwell Automation Publication 2094-UM001H-EN-P - June 2013
Chapter 4
Connector Data and Feature Descriptions
IAM and AM Motor Power and Brake Connector Pinout
Table 35 - Motor Power Connector
Table 36 - Motor Brake/Resistive Brake Connector
MP Pin
Description
Signal
4
Chassis ground
3
Three-phase motor power
W
2
V
1
U
IMPORTANT
Combined motor-power cable length for all axes on the same DC bus must not
exceed 240 m (787 ft) with 460V systems or 160 m (525 ft) with 230V systems.
Drive-to-motor power cables must not exceed 90 m (295.5 ft).
System performance was tested at these cable length specifications. These
limitations also apply when meeting CE requirements.
BC Pin
Description
Signal
6
Motor brake connections
MBRK-
5
MBRK+
4
Motor brake common
COM
3
+24V brake input power
(from LIM module or customer supplied)
PWR
2
RBM module connections
(from RBM module and safety string)
DBRK-
1
DBRK+