Connector Data and Feature Descriptions
Safe Torque-off Connector Pinout
Each 2094-
xCxx-Mxx-S IAM module and 2094-xMxx-S AM module ships with
the (9-pin) wiring-plug header and motion-allowed jumper installed in the safe
torque-off (STO) connector. With the motion-allowed jumper installed, the safe
torque-off feature is not used.
Figure 25 - Motion-allowed Jumper
Headers in this table extend the safe torque-off (STO) connector signals for use
in wiring single and multiple safe torque-off drive configurations, or to defeat
(not use) the safe torque-off feature.
Table 24 - IAM/AM Safe Torque-off 9-pin (STO) Connector
Refer to the Kinetix Safe Torque-off Feature Safety Reference Manual,
publicatio
headers.
1 2
3 4
5 6
7 8
9
1
Motion-allowed Jumper
Wiring Plug Header
Kinetix 6000 IAM/AM Module
(AM module is shown)
Safe Torque-off
(STO) Connector
Safe Torque-off (STO)
Connector Pin
Applies to These STO Connector Headers
Description
Signal
1
• Wiring plug header used in single-drive
applications
• First-drive wiring header
(catalog number 2090-XNSM-W)
used in multiple-drive applications
One side of the normally-closed monitoring contact of relay 2
FDBK2+
2
Other side of the normally-closed monitoring contact of relay 2
FDBK2-
3
One side of the normally-closed monitoring contact of relay 1
FDBK1+
4
Other side of the normally-closed monitoring contact of relay 1
FDBK1-
5
Safety enable 2 input
SAFETY ENABLE2+
6
Return for safety enable power (both inputs)
SAFETY ENABLE-
7
Safety enable 1 input
SAFETY ENABLE1+
8
• Wiring plug header
• Motion-allowed jumper
Power for continuous enable of the safety function, 500 mA max
24V+
9
Power return used for continuous enable of safety function
24V_COM
IMPORTANT
Pins STO-8 and STO-9 (24V+) are used by only the motion-allowed jumper.
When wiring to the wiring-plug header, the 24V supply must come from an
external source.