Digi NS9215 User Manual
Page 483

. . . . .
T I M I N G
Reset and edge sensitive input timing requirements
www.digiembedded.com
483
If an external device driving the reset or edge sensitive input on a Digi processor
cannot meet the 500ns maximum rise and fall time requirement, the signal must be
buffered with a Schmitt trigger device. Here are sample Schmitt trigger device part
numbers:
Manufacturer
Part Number
Description
Fairchild
NC7SP17
Single Schmitt trigger buffer,
available in 5-lead SC70 and 6-lead MicroPak packages
Philips
74LVC1G17GW
Single Schmitt trigger buffer,
available in 5-lead SC70 and SOT 353 packages
TI
SN74LVC1G17DC Single Schmitt trigger buffer,
available in 5-lead SC70 and SOT 353 packages
ON Semi
NL17SZ17DFT2
Single Schmitt trigger buffer,
available in 5-lead SC70 and SOT 353 packages.