Baud rate generator, Baud rates – Digi NS9215 User Manual
Page 387

. . . . .
S E R I A L C O N T R O L M O D U L E : U A R T
Baud rate generator
www.digiembedded.com
387
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B a u d r a t e g e n e r a t o r
The baud rate clock is generated by dividing the system reference clock by a
programmable divisor; use this formula:
BR = CLK
ref
/ (BRD x 16)
The default reference clock for the UARTs is the system reference clock input on
x1_sys_osc. The UART reference clock optionally can be input on GPIO_A[3].
Baud rates
This table shows the baud rates achieved with CLK
ref
set to 29.4912:
UART Interrupt Enable register
(0x104)
ETBEI
0x1
Enable the Transmitter Holding
Register Empty Interrupt. enables the
Wrapper to write a transmit character
to the UART.
Wrapper Configuration register
TX FLOW
Software
1
TX Enabled
RXEN
1
Enable Wrapper receive function
TXEN
1
Enable Wrapper transmit function
Control register
Field
Value
Comment
Divisor
Baud rate
1
1,843,299
2
921,600
4
460,800
8
230,400
16
115,200
32
57,600
48
38,400
64
28,800
96
19,200
128
14,400
192
9,600
384
4,800
768
2,400