Metrohm 732 IC Detector User Manual
Page 181
![background image](/manuals/586520/181/background.png)
6 Interfaces
732 IC Detector / 733 IC Separation Center
174
Object
Meaning
Entry range/Selection
³
Ã
.
M
ark
Trigger marking signal (= key)
1
…
7
…
15
³
Ã
.
Zeroo
ff
Switch off auto-zero (=
1
…
9
…
15
³
Ã
.
Pl
ot
Trigger graphics plot (=
1
…
10
…
15
³
Ã
.
Po
larity
Switch polarity at analog output
1
…
11
…
15
³
Ã
.
S
elect
Select (=
1
…
13
…
15
³
Ã
.
Q
uit
Quit (=
1
…
14
…
15
³
À
.
E
nter
Enter (=
1
…
15
…
15
Ã
.
G
raphics
General graphics parameters
³
Ã
.
G
rid
Grid lines on graphics output
on, off
³
Ã
.
F
rame
Frame on graphics output
on, off
³
À
.
R
ecorder
Setting of printout
³
À
.
W
idth
Relative width of printout
0.4
…
0.8
…
1.0
À
.
P
eripherals
Peripheral instruments
Ã
.
W
ith733
Operation with 733 IC Separation Center
on
, off
À
.
With70
9
Operation with 709 IC Pump
on
, off
&A
ssembly
Basic elements of the assembly
³
Ã.
M
eas
Measurement
³
À
.
S
tate
On/off switching of measurement
on
, off
³
À.
O
utputs
Remote lines
Ã
.
S
mplX
³
Activate (on) or deactivate (off) remote output lines on, off
Ã
.
A
utoEOD
³
Automatic output of EOD on program end and
"return" with loop programs
on
, off
Ã
.
Se
tLines
³
³
³
³
³
³
³
³
³
³
³
³
Set remote outputs 1
…
16:
Interface "709 IC Pump": outputs 1
…
8
Interface "Remote":
outputs 9
…
16
active
setting of a static signal
inactive
resetting of the static signal
pulse
output a pulse (length ca. 150 ms)
off
do not set line
$G
³
Ã
.
L1
Signal of output line
1
(pin 5)
active, inactive, pulse, off
³
Ã
.
L2
Signal of output line
2
(pin18)
active, inactive, pulse, off
³
Ã
.
L3
Signal of output line
3
(pin 4)
active, inactive, pulse, off
³
Ã
.
L4
Signal of output line
4
(pin17)
active, inactive, pulse, off
³
Ã
.
L5
Signal of output line
5
(pin 3)
active, inactive, pulse, off
³
Ã
.
L6
Signal of output line
6
(pin16)
active, inactive, pulse, off
³
Ã
.
L7
Signal of output line
7
(pin 1)
active, inactive, pulse, off
³
Ã
.
L8
Signal of output line
8
(pin 2)
active, inactive, pulse, off
³
Ã
.
L9
Signal of output line
9
(pin 5)
active, inactive, pulse, off
³
Ã
.
L10
Signal of output line 10
(pin18)
active, inactive, pulse, off
³
Ã
.
L11
Signal of output line 11
(pin 4)
active, inactive, pulse, off
³
Ã
.
L12
Signal of output line 12
(pin17)
active, inactive, pulse, off
³
Ã
.
L13
Signal of output line 13
(pin 3)
active, inactive, pulse, off
³
Ã
.
L14
Signal of output line 14
(pin16)
active, inactive, pulse, off
³
Ã
.
L15
Signal of output line 15
(pin 1)
active, inactive, pulse, off
³
À
.
L16
Signal of output line 16
(pin 2)
active, inactive, pulse, off
À
.
R
esetLines
Set remote outputs 1
…
16 to ”off”
$G