The timeout-timer parameter sets the amount of time after which a route is considered unreachable.
The possible value ranges from 9 - 65535. The default is 180 seconds.

The hold-down-timer parameter sets the amount of time during which information about other paths is
ignored. The possible value ranges from 0 - 65535. The default is 180 seconds.

The garbage-collection-timer sets the amount of time after which a route is removed from the rip
routing table. The possible value ranges from 0 - 65535. The default is 120 seconds.

Displaying RIP Information

To display RIP filters, enter the following command at any CLI level.

device# show ip rip

RIP Summary

Default port 520

Administrative distance is 120

Updates every 30 seconds, expire after 180

Holddown lasts 180 seconds, garbage collect after 120

Last broadcast 29, Next Update 27

Need trigger update 0, Next trigger broadcast 1

Minimum update interval 25, Max update Offset 5

Split horizon is on; poison reverse is off

Import metric 1

Prefix List, Inbound : block_223

Prefix List, Outbound : block_223

Route-map, Inbound : Not set

Route-map, Outbound : Not set

Redistribute: CONNECTED Metric : 0 Routemap : Not Set

No Neighbors are configured in RIP Neighbor Filter Table

Syntax: show ip rip

CLI display of neighbor filter information

TABLE 51

Field.

Defiinition

RIP Summary area

Shows the current configuration of RIP on the device.

Static metric

Shows the static metric configuration. ".not defined" means the route map has not been
distributed.

OSPF metric

Shows what OSPF route map has been applied.

Neighbor Filter Table area

Index

The filter number. You assign this number when you configure the filter.