beautypg.com

Motorola DSP96002 User Manual

Page 809

background image

MOTOROLA

27

15. Send command WRITE PDB REGISTER (no GO, no EX).

(ODEC selects PDB as destination for serial data.)

16. ACK

17. Send 32 bits of the target absolute address for the second processor ($xxxxxxxx).

18. ACK

The sequence of instructions described above will be repeated for the remaining proces-
sors in the system. Finally the command controller will select ALL the processors in the
system and will issue in a broadcast manner the synchronous GO command.

19. Send command GO and EX with no register select.

(All the chips will resume fetching from their target addresses synchronously. Note that the trace
counter will count this instruction so the current trace counter may need to be corrected if the
trace mode enable bit in the OSCR has been set.)