Fcopys.x copy sign fcopys.x – Motorola DSP96002 User Manual
Page 302
A - 114
DSP96002 USER’S MANUAL
MOTOROLA
FCOPYS.X
Copy Sign
FCOPYS.X
Operation:
Sign of S
→
D (parallel data bus move)
Assembler Syntax:
FCOPYS.X S,D (move syntax - see the MOVE in-
struction description.)
Description:
Copy the sign of the floating-point operand S to the floating-point operand D. Since both S and D are single
extended precision operands, rounding is not performed.
Input Operand(s) Precision: SEP Floating-Point.
Output Operand Precision: SEP Floating-Point.
CCR Condition Codes:
C
- Not affected.
V
- Not affected.
Z
- Set if result is zero. Cleared otherwise.
N
- Set if result is negative. Cleared otherwise.
I
- Set if result is infinity. Cleared otherwise.
LR
- Not affected.
–
R
- Not affected.
A
- Not affected.
ER Status Bits:
INX
-Always cleared.
DZ
-Always cleared.
UNF
-Always cleared.
OVF
-Always cleared.
OPERR-Always cleared.
SNAN -Set if operand is a signaling NaN. Cleared otherwise.
NAN
-Set if result is a NaN. Cleared otherwise.
UNCC -Always cleared.
IER Flags: Flags changed according to standard definition.