Or logical inclusive or or – Motorola DSP96002 User Manual
Page 473
MOTOROLA
DSP96002 USER’S MANUAL
A - 285
OR
Logical Inclusive OR
OR
(u u)
D
d d d
Dn.L
n n n
where nnn = 0-7
S
s s s
Dn.L
n n n
where nnn = 0-7
Timing: 2 + mv oscillator clock cycles
Memory: 1 + mv program words
00
0sss
uu01
1ddd
31
14 13
0
OPTIONAL EFFECTIVE ADDRESS EXTENSION OR IMMEDIATE LONG DATA
DATA BUS MOVE FIELD
Operation:
D.L v S.L
→
D.L (parallel data bus move)
Assembler Syntax:
OR S,D
( See the MOVE instruction description.)
Description:
Logically inclusive OR the low portion of the two specified operands and store the result in the low portion
of D.
Input Operand(s) Precision: 32-bit integer.
Output Operand Precision: 32-bit integer.
CCR Condition Codes:
C
- Not affected.
V
- Always cleared.
Z
- Set if result is zero. Cleared otherwise.
N
- Set if result is negative. Cleared otherwise.
I
- Not affected.
LR
- Not affected.
–
R
- Not affected.
A
- Not affected.
ER Status Bits: Not affected.
IER Flags: Not affected.
Instruction Format: OR S,D ( See the MOVE instruction description.)
Instruction Fields: