Andc logical and with complement andc – Motorola DSP96002 User Manual
Page 211
MOTOROLA
DSP96002 USER’S MANUAL
A - 23
ANDC
Logical AND with Complement
ANDC
DATA BUS MOVE FIELD
11
0sss
1000
1ddd
31
14 13
0
OPTIONAL EFFECTIVE ADDRESS EXTENSION OR IMMEDIATE LONG DATA
Operation:
D.L & ~S.L
→
D.L (parallel data bus move)
Assembler Syntax:
ANDC S,D (move syntax - see the MOVE instruc-
tion description.)
Description:
Logically AND the low portion of D with the logical complement of the low portion of S, and store the result
in the low portion of D.
Input Operand(s) Precision: 32-bit integer.
Output Operand Precision: 32-bit integer.
CCR Condition Codes:
C
- Not affected.
V
- Always cleared.
Z
- Set if result is zero. Cleared otherwise.
N
- Set if result is negative. Cleared otherwise.
I
- Not affected.
LR - Not affected.
–
R - Not affected.
A
- Not affected.
ER Status Bits:
Not affected.
IER Flags:
Not affected.
Instruction Format: AND S,D (move syntax - see the MOVE instruction description.)