Motorola DSP96002 User Manual
Page 744
MOTOROLA
DSP96002 USER’S MANUAL
C-21
or truncation. If the register is read by a single precision move, completely incorrect data will be obtained;
see the discussion in Section C.1.5.1.1.3.
C.1.5.1.2.3
Data ALU Results/Move Compatibility Summary
Figure C-16 summarizes what happens when Data ALU operation results of a certain range are stored in
the destination register, and the register is read by a certain kind of move.
All cases where "move out type"=SP and "move out result"=WRONG can be corrected by rounding in the
instruction (using the .S option). The case where "move out type"=SP and "move out result"=TRUNC can
also be corrected by using the .S option.