FABS.X
Absolute Value
FABS.X
Operation:
D
→
D (parallel data bus move)
Assembler Syntax:
FABS.X D (move syntax - see the MOVE instruc-
tion description.)
Description:
Take the absolute value of the destination operand and store the result in the destination operand D.
Input Operand(s) Precision: SEP Floating-Point.
Output Operand Precision: SEP Floating-Point.
CCR Condition Codes:
C
- Not affected.
V
- Not affected.
Z
- Set if result is zero. Cleared otherwise.
N
- Always cleared.
I
- Set if result is infinity. Cleared otherwise.
LR
- Not affected.
–
R
- Not affected.
A
- Not affected.
ER Status Bits:
INX
-Always cleared.
DZ
-Always cleared.
UNF
-Always cleared.
OVF
-Always cleared.
OPERR-Always cleared.
SNAN -Set if operand is a signaling NaN. Cleared otherwise.
NAN
-Set if result is a NaN. Cleared otherwise.
UNCC -Always cleared.