A - 227
U
Move Update
U
(Effective Address Calculation)
Instruction Fields:
ea Rn - R0-R7 (Update addressing modes only)
Timing: 0 oscillator clock cycles
Memory: 0 program words
Operation:
Opcode Operation
ea
Assembler Syntax:
Opcode-Operands
ea
Description:
The specified effective address calculation is executed. The specified address register is updated accord-
ing to the addressing mode. All update addressing modes may be used. The No Update mode (Rn) is
useful, in conjunction with the MOVETA instruction, to test address registers.
Instruction Format - Opcode-operands: ea
0001
0101
1011
MMMR
uu
uuuu
uuuu
uuuu
31
14 13
0
Move